difference between water and fire tube boiler

Details


  • Production capacity: 7-70 MW
  • Work pressure: 1.0-1.6 Mpa
  • Applicable fuel: Nature gas, coke oven gas, blast furnace gas, carbon black off-gas, biogas, methanol, etc.
  • Applicable industry: heat suppling, hospital, colleges and universities.


Product introduction

  SZS Series Boiler is double drums, longitudinal arranged, "D" type chamber structure. Furnace is on right side and convection tube bundle is on the left. The body is fixed on the basement by middle and both end flexible supports and make the boiler to expand horizontally to sideways. Around furnace is membrane water cooling tube wall. Furnace and tube bundle is totally separated by the membrane water tube cooling wall at the left side of the furnace. The back part of bundle is sparse shift structure, front part is aligned structure. Smoke from furnace outlet enters re-burning chamber, bundle area, and then from left front part enters spiral fin coil economizer and condenser, finally discharged to atmosphere through chimney.





Safety

  Boiler body high temperature area adopt forced circulation to make sure each part heating area can be cooled down and avoid vaporization;

  Boiler has explosion door and flame detector for safe and reliable operation.

  comb plates are used as the sealing between both sides of boiler and tube bundle all use to avoid leakage of condensate and gas which is caused by refractory concrete sealing.

  air tightness test is done before leaving the factory to ensure no leakage of gas.

environmental protection

  Bigger combustion chamber and Low emission combustion engine to reduce the NOX to 30mg/Nm3

  Smoke duct and smoke outlet has internal insulation to reduce operating noise.

  Combustion chamber use full membrane water cooling wall structure, pressurized firing without smoke mixture.

energy conservation

  Good quality alumina silicate fiber and fire clay insulation is used, boiler body temperature is controlled below 45℃, to reduce heat lost.

  Combustion chamber use narrow distance tube membrane water cooling wall which has good air tightness, and reduce heat lost and increase boiler thermal efficiency.

  Inside of Inspection holes use high-alumina refractory and man hole cover sealing devices, it solved the high temperature of this part by using refractory brick

Convenience

  Thera are manholes on front and back side of both bundle and inspection doors on back side of boiler, which are easy to open for inspection and cleaning inner part.

longer lifespan

  Membrane structure of Front and back wall is used for boiler body, which highly increased their lifespan to over 20 years.

  The key part such as material cutting, rolling, drilling are proceeded by advanced CNC machining process to reduce the assemble stress and extend boiler working lifetime.

  flutter prevention fastener is used for high temperature part convection tube, which avoid bundle tube cracking problem.

  Longitudinal and girth joint adopt advanced automatic submerged-arc welding for good welding quality. All longitudinal and girth joint will have 100% radiographic inspection.

 
Items
Model
SZS7-1.0/115/70-Q SZS10.5-1.0/115/70-Q SZS14-1.25/115/70-Q SZS17.5-1.25/115/70-Q SZS21-1.25/130/70-Q SZS29-1.25/130/70-Q SZS46-1.6/130/70-Q SZS58-1.6/130/70-Q SZS70-1.6/130/70-Q SZS116-1.6/130/70-Q
Rated thermal power(MW) 7.0 10.5 14.0 17.5 21.0 29 46 58 70 116
Rated working pressure(MPa) 1.0 1.0 1.25 1.25 1.25 1.25 1.6 1.6 1.6 1.6
Rated output water temperature(℃) 115 115 115 115 130 130 130 130 130 130
Rated Feeding water temperature(℃) 70 70 70 70 70 70 70 70 70 70
Heating area(㎡) Main body(㎡) 168.0 220.0 245.30 284.40 394.75 428.1 1065.9 1225.7 1408.4 6164.8
Condenser (㎡) 164.0 306.0 527.0 645.1 738.3 990.8 985.3 1292.5 1642.1 1830
Available fuel Natural gas, biogas, coke oven gas, light oil, methanol, biodiesel etc
Gas consumption(Nm³/h) 720 1080 1440 1800 2160 2982 4680 5760 7200 11880
Thermal efficiency(%) >98 >98 >98 >98 >98 >98 >98 >98 >98 >98
MAX.transportation weight(t) 42.0 48.0 52.5 57.5 65.0 72.5 散件12.6 散件13.8 散件16 散件20
MAX. transportation dimension LxWxH(m) 7.87x3.40x3.34 8.85x3.85x3.93 8.51x3.85x3.75 9.31x3.77x3.75 10.10x4.13x4.15 10.90x4.13x4.15 11.00xΦ1.45 11.10xΦ1.46 12.00xΦ1.66 12.50xΦ1.66

CONTACT FORM



firetube boiler watertube boilers whats the difference Firetube or Watertube? Whats the difference? Boilers come in many different sizes, shapes and designs. This creates quite a challenge for those of us that do not Vertical boiler with horizontal fire-tubes Wikipedia The Clarke Chapman boiler is similar to the Cochran type, with the difference that the top of the boiler shell is a shallow dome rather than a hemisphere. Marine steam boiler information for technicians and engineers By Lars Josefsson. Important marine steam boiler information for technicians and engineers using marine boilers, water-tube steam boilers or fire-tube steam boilers 12 Ways To Avoid Boiler Tube Corrosion APPENDIX D 1 12 Ways To Avoid Boiler Tube Corrosion By: H. F. Hinst Plant Metallurgist Tubular Products Division, Keystone Plant The Babcock Wilcox Company Three-drum boiler Wikipedia, the free encyclopedia Three-drum boilers are a class of water-tube boiler used to generate steam, typically to power ships. They are compact and of high evaporative power, factors that Steam/water circulation design KTH | Energiteknik 5 Fire tube boilers generally have tubes with a diameter of 5 cm or larger. They are usually straight and relatively short so that the hot gases of combustion Boilers , Weil Mclain Boilers , Burnham Boilers Weil Mclain Boilers are one of our specialties on our website. We also sell Buderus Boilers, Weil Mclain Ultra Boilers, Biasi Boilers and more. We offer several Boiler Exam 1c Minnesota ProProfs Quiz 8. 1)a (RPZ) reduced pressure zone or back flow preventer prevents contaninated water from entering the domestic water supply. Boiler Questions and Answers Lars Josefsson Question: Cavitation in a two flow line We have a steam genereting facilty using process heat. The condenser is a vertical condenser with process vapours on tube side Boiler operation SlideShare Sep 19, 2012Boiler operation 1. Boilers Thermal Fluid Heaters 1 2. Training Agenda: BoilerIntroductionType of boilersAssessment of a boilerEnergy efficiency Difference between Fire tube boiler and water tube boiler Structure Both are shell and tube type of boiler, fire tube have hot gases inside the tube while water tube have water inside the tube and hot gases surrounding them firetube boiler watertube boilers whats the difference Firetube or Watertube? Whats the difference? The choice between a firetube design and a water tube modern forced draft design is the ultimate in water boiler Fire-tube boiler Wikipedia, the free encyclopedia A fire-tube boiler is a type of boiler in which hot gases from a fire pass through one or (many) this is still not considered to be a water-tube boiler. Water Tube boiler vs Fire Tube Boiler,Difference between Water Tube vs Fire Tube Boiler is comparison between two types boiler which is viewed from several aspects. Water tube and fire tube boiler is steam boiler Difference between fire tube boiler and water tube boiler? The difference between the two is that the Water tube boilers aresafer and last much longer than the fire tube boiler. fire tube boilers, water tube boilers-ZOZEN Boiler What Is The Difference Between Fire Tube Boiler and Water Tube Boiler Water-tube boiler Wikipedia, the free encyclopedia A watertube boiler (also spelled water-tube and water tube) is a type of boiler in which water circulates in tubes heated externally by the fire. Steam Boiler: Water Tube vs Fire Tube Boiler Water tube and fire tube boiler is steam boiler classification which is categorized From explanation above comparison between Water Tube vs Fire Tube Boiler can Difference between water boilers and fire tube boilers? Water Tube Boilers Suitable for high steam pressure (above 500 psig) and temperature(to 1000 F) and large capacities exceeding millions of lb/h of steam. Difference between Fire Tube Boiler and Water Tube Boiler fire tube boiler and water tube boiler, Difference between fire tube boiler and water tube boiler Difference between fire tube boiler and water tube boiler Feb 28, 2016i) The water circulates inside the tubes which are surrounded by the hot flue gases from the furnace. Difference Between Smoke Tube Boiler And Water Tube Boiler smoke tube boiler and water tube boiler are the main Difference Between Smoke Tube Boiler And This boiler is also called fire tube boiler, fire tube Choosing The Right Boiler: Watertube vs. Firetube Choosing The Right Boiler: Lets not forget that there is a tremendous difference in water volume between a firetube boiler and a watertube boiler. Difference Between Fire Tube Boiler and Water Tube Boiler The difference between fire tube boiler and water tube boiler can be done on various points. These points includes types of fluid flows within the tubes, steam