bangladesh boiler regulations

Details


  • Production capacity: 7-70 MW
  • Work pressure: 1.0-1.6 Mpa
  • Applicable fuel: Nature gas, coke oven gas, blast furnace gas, carbon black off-gas, biogas, methanol, etc.
  • Applicable industry: heat suppling, hospital, colleges and universities.


Product introduction

  SZS Series Boiler is double drums, longitudinal arranged, "D" type chamber structure. Furnace is on right side and convection tube bundle is on the left. The body is fixed on the basement by middle and both end flexible supports and make the boiler to expand horizontally to sideways. Around furnace is membrane water cooling tube wall. Furnace and tube bundle is totally separated by the membrane water tube cooling wall at the left side of the furnace. The back part of bundle is sparse shift structure, front part is aligned structure. Smoke from furnace outlet enters re-burning chamber, bundle area, and then from left front part enters spiral fin coil economizer and condenser, finally discharged to atmosphere through chimney.





Safety

  Boiler body high temperature area adopt forced circulation to make sure each part heating area can be cooled down and avoid vaporization;

  Boiler has explosion door and flame detector for safe and reliable operation.

  comb plates are used as the sealing between both sides of boiler and tube bundle all use to avoid leakage of condensate and gas which is caused by refractory concrete sealing.

  air tightness test is done before leaving the factory to ensure no leakage of gas.

environmental protection

  Bigger combustion chamber and Low emission combustion engine to reduce the NOX to 30mg/Nm3

  Smoke duct and smoke outlet has internal insulation to reduce operating noise.

  Combustion chamber use full membrane water cooling wall structure, pressurized firing without smoke mixture.

energy conservation

  Good quality alumina silicate fiber and fire clay insulation is used, boiler body temperature is controlled below 45℃, to reduce heat lost.

  Combustion chamber use narrow distance tube membrane water cooling wall which has good air tightness, and reduce heat lost and increase boiler thermal efficiency.

  Inside of Inspection holes use high-alumina refractory and man hole cover sealing devices, it solved the high temperature of this part by using refractory brick

Convenience

  Thera are manholes on front and back side of both bundle and inspection doors on back side of boiler, which are easy to open for inspection and cleaning inner part.

longer lifespan

  Membrane structure of Front and back wall is used for boiler body, which highly increased their lifespan to over 20 years.

  The key part such as material cutting, rolling, drilling are proceeded by advanced CNC machining process to reduce the assemble stress and extend boiler working lifetime.

  flutter prevention fastener is used for high temperature part convection tube, which avoid bundle tube cracking problem.

  Longitudinal and girth joint adopt advanced automatic submerged-arc welding for good welding quality. All longitudinal and girth joint will have 100% radiographic inspection.

 
Items
Model
SZS7-1.0/115/70-Q SZS10.5-1.0/115/70-Q SZS14-1.25/115/70-Q SZS17.5-1.25/115/70-Q SZS21-1.25/130/70-Q SZS29-1.25/130/70-Q SZS46-1.6/130/70-Q SZS58-1.6/130/70-Q SZS70-1.6/130/70-Q SZS116-1.6/130/70-Q
Rated thermal power(MW) 7.0 10.5 14.0 17.5 21.0 29 46 58 70 116
Rated working pressure(MPa) 1.0 1.0 1.25 1.25 1.25 1.25 1.6 1.6 1.6 1.6
Rated output water temperature(℃) 115 115 115 115 130 130 130 130 130 130
Rated Feeding water temperature(℃) 70 70 70 70 70 70 70 70 70 70
Heating area(㎡) Main body(㎡) 168.0 220.0 245.30 284.40 394.75 428.1 1065.9 1225.7 1408.4 6164.8
Condenser (㎡) 164.0 306.0 527.0 645.1 738.3 990.8 985.3 1292.5 1642.1 1830
Available fuel Natural gas, biogas, coke oven gas, light oil, methanol, biodiesel etc
Gas consumption(Nm³/h) 720 1080 1440 1800 2160 2982 4680 5760 7200 11880
Thermal efficiency(%) >98 >98 >98 >98 >98 >98 >98 >98 >98 >98
MAX.transportation weight(t) 42.0 48.0 52.5 57.5 65.0 72.5 散件12.6 散件13.8 散件16 散件20
MAX. transportation dimension LxWxH(m) 7.87x3.40x3.34 8.85x3.85x3.93 8.51x3.85x3.75 9.31x3.77x3.75 10.10x4.13x4.15 10.90x4.13x4.15 11.00xΦ1.45 11.10xΦ1.46 12.00xΦ1.66 12.50xΦ1.66

CONTACT FORM



LARA Boiler Examination Schedule, Licensing Information and Application for Boiler Operator or Stationary Engineer Examination knowledge of all federal rules and regulations regarding the installation of a boiler that has Boilers Act, 1923 (Act No. V of 1923). An Act to consolidate and amend the law relating to steam-boilers. Use of boiler pending grant of certificate. 11. Publication of regulations and rules. 32. Building Standard The Bangladesh Accord on Fire and Building Dec 30, 2013 The Accord on Fire and Building Safety in Bangladesh. Building Standard . 1.6.3.3 Boiler Act, 1923, Section 2 (b) and 6. 1.6.3.4 Petroleum Act Bangladesh Boiler Regulation- 1951 [Amended the Boiler Office Bangladesh Boiler Regulation- 1951 boilers constructed in Bangladesh, an. Welcome to the Boiler Office Jun 22, 2014 of boilers . The following Act, Rules and Regulations now en-force in Bangladesh. 1. The Boiler Act, 1923. 2. The Boiler Regulation, 1951. 3. Boilers Act, 1923 Laws of Bangladesh Ministry of Law, Justice (a) accident means an explosion of a boiler or steam-pipe or any damage to a boiler (e) prescribed means prescribed by regulations or rules made this Act; Bangladesh Power Development Board BPDB The boilers shall be open-air installed for firing with coal. The steam turbine declaration of conformance with Bangladesh regulations. spare part lists for Survey report _1_ Bangladesh Legal Aid and Services Trust Bangladesh Standards and Testing Institute (BSTI), Office of the Chief Inspector of By properly applying of Boiler Act, Rules and Regulations this department. BD Series Crown Boiler BD-111 4 111,000 97,000 547 -90 2.75 8x8x15 21 6 11V: 475 86.4 These boilers are low pressure sectional cast iron boilers . these regulations is required. Survey report _1_ Bangladesh Legal Aid and Services Trust Bangladesh Standards and Testing Institute (BSTI), Office of the Chief Inspector of By properly applying of Boiler Act, Rules and Regulations this department. Act Laws of Bangladesh Ministry of Law, Justice and Trial of offences. 27A. Boilers Board. 28. Power to make regulations. 29. Power to make rules. 30. Penalty for breach of rules. 31. Publication of regulations and Inspections and Audits for Boilers and Pressure Vessels In most countries, manufacturers of boilers and pressure vessels must comply with strict regulations and codes in order to market their equipment. This is their BD-RMG Gas Pressure Regulators Honeywell Process Solutions BD-RMG 226 H is a spring-loaded, diaphragm operated gas pressure regulator fuel gas feeds in industrial burners, heater units, boilers and other equipment. Regulator offers accurate, safe and dependable gas regulation capabilities in a THE BOILERS ACT, 1923 Labour 923. 2 be prescribed by regulations for inspection and certification of boilers and boiler. Delegated Legislation | Mohammad Mohiuddin Academia.edu Boiler Regulation,1951, Depositories Regulations, 2000 Pension These rules may be called the Bangladesh Civil Service Recruitment Rules, 1981. A Handbook on the Bangladesh Labour Act 2006 ILO Laws other than labour law 2006 applicable in Bangladesh The Inland Water Transport (Regulation ofEmployment) Act, 1992 The Boilers Rules, 1928.